PU Ducting Hose is intended for suction and conveying of selected abrasive solids, dust, powders, wood chips and granules, as well as ventilation and industrial-vacuum applications. Particle characteristics, airflow, vacuum, temperature, static risk and installation conditions must be reviewed before selection.

PU Ducting Hose Construction

Wall material Ester-based polyurethane
Spiral reinforcement Copper-plated steel wire
Wall thickness 0.4 mm
Wall appearance Transparent

Documented Temperature Information

  • Stated continuous temperature range: -40°C to 90°C
  • Stated short-time temperature: up to 125°C

The applicable temperature depends on the conveyed material, airflow, exposure time, vacuum and installation. Confirm the selected hose rating before use.

Typical Industrial Applications

  • Dust and powder extraction
  • Wood-chip and granule conveying
  • Ventilation systems
  • Industrial vacuum cleaners
  • Suction and transport of selected abrasive solids

Abrasion, particle size, static generation, airflow velocity and hose wear must be evaluated for the actual application.

Information Needed for Ducting Hose Selection

  • Material being conveyed, particle size and abrasion characteristics
  • Airflow, suction pressure and required vacuum
  • Operating and peak temperature
  • Required internal diameter and hose length
  • Bend radius, movement and compression requirements
  • Static risk, grounding and site-area classification
  • Connection, clamp and support details

Static Electricity and Grounding Considerations

The existing product information states that static electricity may be conducted by grounding the steel wire. Grounding effectiveness and suitability must be designed and verified for the actual equipment, conveyed material and site requirements. Do not assume that the hose is intrinsically safe or certified for a hazardous area.

Installation and Inspection

  • Connect and support the hose without crushing or overstretching it
  • Maintain the approved bend radius and avoid sharp edges
  • Ground the spiral wire only according to the site’s engineered procedure
  • Inspect the wall, spiral and connections for abrasion or damage
  • Replace the hose according to the site’s wear and maintenance criteria

Frequently Asked Questions

Can this hose convey every abrasive powder or granule?

No. Suitability depends on particle size, hardness, temperature, velocity, vacuum, bend routing and expected wear.

Does the steel spiral automatically make the hose anti-static?

No. The spiral must be correctly grounded and the complete installation must be assessed for the actual static and hazardous-area requirements.

What information is required for a quotation?

Provide the material, particle size, temperature, airflow or vacuum, hose diameter and length, routing, grounding and connection requirements.

Request a PU Ducting Hose Quote in Malaysia